Candida auris PCR
Real-time PCR for Candida auris
*Centers for Disease Control and Prevention. (2021, July 22). Candida auris. Centers for Disease Control and Prevention. Retrieved March 28, 2023 from https://www.cdc.gov/fungal/candida-auris/index.html
** Lyman M et al. Worsening Spread of Candida auris in the United States, 2019 to 2021. Ann Intern Med. 2023 Mar 21. doi: 10.7326/M22-3469. Epub ahead of print. PMID: 36940442.
Candida auris PCR for fungal detection and identification
Our Candida auris real-time PCR reagents are designed to provide accurate detection of this emerging fungus. The EGMDx research and development team designed our ASR§ and RUO‡ reagents to meet the needs of CLIA high-complexity clinical labs and reference laboratories, allowing your own lab’s design creativity in developing an LDT (laboratory developed test) or in C. auris research.
C. AURIS TESTING PORTFOLIO
C. auris detection and amplification
C. auris echinocandin resistance mutation detection
C. auris fluconazole resistance mutation detection
Real-time PCR automated lab system
CANDIDA FAMILY OF PRIMERS, PROBES & REAGENTS
PRODUCT # | ELITECHGROUP PRODUCT NAME | REPORTABLE RESULTS |
M800729 | DSQ Alert™ Candida auris Primer Mix ASR | Candida auris |
M800730 | DSQ Alert Candida auris Probe Mix ASR | Candida auris |
M400920 | MGB Alert® Candida auris with echinocandin resistance RUO Detection Reagent | C. auris echinocandin resistance mutations present (with melt |
M400861 | MGB Alert Candida auris with fluconazole resistance RUO Detection Reagent | C. auris fluconazole resistance mutations present (with melt |
M400869 | MGB Alert Candida species with C. auris RUO Detection Reagent | C. albicans, C. auris, C. dubliniensis, C. glabrata |
§Analyte Specific Reagent. Analytical and performance characteristics are not established.
‡For Research Use Only. Not for use in diagnostic procedures.
INFECTIOUS DISEASE TEST PORTFOLIO
Real-Time PCR testing for laboratories
ELITechGroup MDx set an industry standard in real-time PCR with the introduction of minor groove binder (MGB) probe technology, featured in our MGB Alert® products. MGB probe technology has long been the gold standard for hybridization probes that allow for melt curve analysis. Adding to our legacy of innovation, we now offer DSQ Alert™ probe technology, an evolution in MGB probe chemistry. Our DSQ Alert reagents feature our newest proprietary duplex stabilizing quencher chemistry in hydrolysis probes, offering enhanced signal-to-noise fluorescence and DNA duplex stability. All test reagents may be used on ELITechGroup MDx proprietary instrument systems and on most open channel platforms.
Our PCR offerings
- Adenovirus§
- Aspergillus spp.‡
- Babesia‡
- Bartonella‡
- BKV§
- Bordetella P/PP§
- Borrelia‡
- Borrelia RF‡
- Candida auris§
- C. auris with echinocandin resistance‡
- C. auris with fluconazole resistance‡
- Candida species‡
- Carbapenem-resistant Enterobacterales (CRE)‡
- Chikungunya‡
- Chlamydia pneumoniae‡
- CMV§
- Coccidioides‡
- Cryptococcus species‡
- Dengue 1-4‡
- EBV§
- Ehrlichia/Anaplasma‡
- Enterovirus§
- GUD-1 HSV 1&2 / T. pallidum‡
- GUD-2 H. ducreyi /
C. trachomatis L1-3‡ - Hepatitis E virus‡
- HHV-6§
- HHV-8§
- Histoplasma/Blastomyces‡
- hMPV§
- HSV 1&2*
- Influenza A/B/RSV‡
- JCV§
- Legionella pneumophila§
- Legionella species§
- Malaria‡
- MG with fluoroquinolone resistance‡
- MG with macrolide resistance‡
- MPXV/OPXV‡
- MRSA/SA*
- Mucorales‡
- Mumps‡
- MTB speciation‡
- Mycoplasma pneumoniae‡
- HT Adenovirus‡
- HT Candida auris§
- HT HHV-6‡
- HT HSV 1&2‡
- HT OPXV‡
- HT Parvovirus B19‡
- HT P. jirovecii‡
Master Mixes
In Development
- HT HDV
- HT HSV 1&2/VZV
- HT Legionella
- HT Norovirus GI/II
*IVD/EUA
§Analyte Specific Reagent. Analytical and performance characteristics are not established.
‡For Research Use Only. Not for use in diagnostic procedures.
MOLECULAR DIAGNOSTICS SYSTEM
The ELITe BeGenius®
Extraction, amplification, results.
With automated extraction, amplification, and results interpretation, the ELITe BeGenius is a sample-to-result solution for your lab. A 3-hour turnaround time means up to 3 hours of walkaway time per run.
Bring more power and flexibility into your lab.
Open mode allows a customizable workflow. 24 PCR wells offer independent thermocycling capability. The ELITe BeGenius features:
- Full automation with onboard extraction and real-time PCR
- Total nucleic acid extraction of RNA and DNA
- Open system capability
- 24 PCR wells, each with independent thermocycling capability
- Multiple tests from each eluate
- Post amplification melt curve option
- Qualitative and quantitative capable
- Up to 72 sample results in an 8-hour shift
- Onboard cooled storage of samples, eluates, and reagents
- 6 optical channels with cross-talk customization
- Automated results interpretation
- LIS integration
ELITechGroup Corporate
At a global corporate level, ELITechGroup is an integrated in-vitro diagnostics company that develops, manufactures and markets a wide range of diagnostic products and solutions, including reagents, instruments, and software. More than 650 employees make ELITechGroup a trusted partner in the IVD industry, serving hospitals and diagnostic laboratories in more than 100 countries through direct sales and third-party distribution.
To optimally serve customers in an ever-evolving IVD market, ELITechGroup is organized into four business units dedicated to specific IVD technologies and market segments: Molecular Diagnostics (MDx), Clinical Chemistry, Biomedical Systems, and Microbiology.
ELITechGroup Molecular Diagnostics US
ELITechGroup MDx LLC is the company’s US Molecular Diagnostics entity, based in Bothell, WA. The US MDx group serves the needs of clinical and research laboratories alike, offering an extensive range of molecular diagnostics products.
The US product portfolio includes the fully automated sample-to-result ELITe BeGenius instrument system and a growing menu of infectious disease tests and reagents that feature the innovative MGB Alert and DSQ Alertâ„¢ probe chemistries.
Why ELITechGroup?
Extensive IP portfolio
Inventors of MGB probes
cGMP compliant, ISO13485 certified
High throughput oligonucleotide manufacturing
25,000 sq. ft. corporate office in Bothell, WA