The use of oligonucleotides modified with 3′-MGB-Quenchers and 5′-Fluorophores is limited to human IVD applications only. ELITechGroup MDx holds patents on MGB, DSQ, AquaPhluor dyes, Super Bases, and oligonucleotide applications. Research-scale oligonucleotides containing these technologies are available for use without a license for research applications. Licensing may be required for large-scale orders and non-research use.
Required
A short, human-readable label for this oligo. It appears on your quote, order confirmation, and Certificate of Analysis. It is not part of the sequence.
Tips:
- Use something you'll recognize later, e.g. "Probe-01".
- 3–40 characters: letters, numbers, spaces and dashes.
- Duplicate labels are allowed but not recommended.
IL6-probe-FAM-BHQ1
Optional for most orders, but required if this is a cGMP re-order, in which case it must be the ELITechGroup part number for the oligo you are re-ordering.
If the order is not cGMP, use the field for your own part number, or leave it blank.
Tips:
- cGMP re-order? Enter the ELITechGroup part number, not your own.
- Otherwise this is free for your own reference — a catalog code, an internal SKU, or nothing at all.
- Part Number is printed on the vial label, alongside Oligo Description. Notes is not.
- Up to 14 characters.
M830192
Required
The oligo itself, written 5′ to 3′. Natural nucleobases go in as UPPER CASE A, C, G and T. The field is case-sensitive, and some modification codes deliberately contain lower-case letters, so a sequence copied from a lower-case source will not analyse.
Modifications are added as bracketed codes, either by typing them or with the Build Sequence buttons below the field. Maximum 45 bases.
Tips:
- UPPER CASE for A, C, G and T. Lower case inside a modification code is intentional — leave it as the picker inserts it.
- Maximum 45 bases. A longer sequence is rejected with an error rather than truncated.
- Spaces and line breaks are ignored, so a sequence pasted in blocks of ten still prices correctly.
- Sequence Assembly, in the Oligo Analysis panel, is an OUTPUT — it cannot be pasted back into this field.
[FAM]ACGTACGTACGTACGTACGT[DSQ]
Five catalogs of modifications — fluorophores, quenchers, modified nucleosides, MGB and linkers. Each opens a searchable list showing the most commonly ordered items first, then the full category.
Choosing one inserts its bracketed code at the cursor in the Sequence field. It never replaces what is already there, so place the cursor where you want the modification before you pick it.
Tips:
- Put the cursor where the modification belongs FIRST — insertion happens at the caret, not at the end of the sequence.
- Nothing is replaced or overwritten, so an accidental insert can simply be deleted.
- Search matches the name, description, abbreviation, part number and the bracketed code itself.
- You can type a code by hand instead — the picker exists so you do not have to remember the spelling.
[FAM] at the 5′ end, [DSQ] at the 3′ end
Required
How much oligo we synthesize. Scale sets the starting synthesis column, so it drives both price and the amount you receive — not the concentration, which is set by Formulation.
200 nmol and 1 µmol are fixed synthesis scales: the yield you get back depends on the length of the sequence and on the purification you choose. Guaranteed nmol works the other way round — you name the amount you need delivered and we synthesize whatever it takes to get there.
Tips:
- 200 nmol suits most qPCR probes and primers.
- Choose Guaranteed nmol when you need a specific delivered amount rather than a specific synthesis scale.
- Guaranteed orders carry a flat service fee and are priced per nmol delivered.
200 nmol
Required
How much of the crude synthesis product is removed before we ship. Heavier purification raises purity and lowers yield, which is why the same scale returns less material at a higher grade.
Precipitation and DMT-on Crude are the standard grades for unmodified primers. HPLC Purification is the usual choice for dual-labelled probes, where an unpurified failure sequence still fluoresces. Dual HPLC ≥90% by Mass Spec adds a second pass and a mass-spec purity confirmation.
Tips:
- Dual-labelled probes: HPLC or better, every time.
- Unmodified primers for routine PCR: Precipitation is normally enough.
- Purification lowers yield, so pair a heavy grade with a larger scale.
HPLC Purification
Required
How the finished oligo is shipped: dried down, or resuspended at a stated concentration in a stated buffer.
Dry ships as a lyophilized pellet for you to resuspend — the most stable option for long storage and the cheapest to ship. Every other choice is a ready-to-use solution at a fixed concentration in Tris/EDTA, which saves a pipetting step and removes any doubt about the final concentration.
Tips:
- Dry is the right default unless you have a reason to want a solution.
- A pre-formulated solution is worth it for assays where concentration accuracy matters more than shelf life.
- Store dried oligos at −20 °C; store solutions at −20 °C and avoid repeated freeze–thaw.
Dry
Required
The quality-control data we run on your oligo and return with it.
Mass Spec (included) is run on every order at no extra cost and confirms the molecular weight, which is what catches a mis-synthesis or a missing modification. Analytical RP-HPLC adds a chromatographic purity trace, which is what you want on file when the oligo is going into a validated or regulated assay.
Tips:
- Mass spec is already included — you never lose it by not upgrading.
- Add Analytical RP-HPLC when you need a documented purity figure, not just an identity check.
Mass Spec (included)
Required
The documentation and quality system the order is manufactured under. This does not change the oligo; it changes the paperwork that comes with it and the process it was made by.
Research grade is for research use only. CoA (Research grade) adds a signed Certificate of Analysis. cGMP (ISO 13485) manufactures the order under our ISO 13485 quality system, which is what a diagnostic or clinical workflow needs.
Tips:
- Ask for a CoA if your lab has to file one per lot.
- Choose cGMP (ISO 13485) for anything feeding a diagnostic assay.
- A first-time ISO 13485:2016 order adds about three business days — see the note under this group.
Research grade
Upload one .xlsx file and every row in it is priced and added to your cart, in place of building oligos one at a time. Start from the example file — the columns are read by position, so keep them in the order the example uses.
Tips:
- Eleven columns, in this order: Oligo Description, Part Number, Notes, Sequence, Synthesis Method, Scale, Guaranteed nmol, Purification, Formulation, Analysis, Quality.
- The first row is treated as headings and skipped.
- Every row needs an Oligo Description and a Sequence; rows missing either are skipped.
- Purification, Formulation, Analysis and Quality must match the option names on the Optional Services step.
- Rows are priced one at a time and added to your cart as they succeed. Any row that fails is listed, with a .csv of just those rows to fix and re-upload.
bulk-upload-sample.xlsx